DVSA compliant commercial vehicle ATF inspection pit with
- 2 x 900mm wide escape tunnels up to 3m long, comes with 30mm cover plates incorporated.
- One end of the pit with escape ladder the other end to have building regulation compliant 900mm wide durbar treaded staircase.
- Doubled up 150mm x 75mm channel jacking rails
- Raised side tracks for step plate, internal trunking to accept lighting and 110v sockets
- 11 x 1.5m IP56 lights, 2 x 110v sockets and termination boxes
- Fully braced external walls and floor at less than 1m interval
- 5mm thick steel with pressed recessed sides
- 6mm thick pressed durbar floor sloping to central sump
- Bolt in top rail sections for installation of jack (Jack optional extra).
- Integrated hydraulic side box for play detector pump unit and solid duct work for hoses to travel under pit.
- Exterior black container paint finish, internal de-greased abraded prior to three coats of zinc phosphate white finished in gloss white enamel.
- Air hose brackets and pipe with two take-off points.
- Dig plan, installation instructions and structural calculations.
- Supplied as both bolt to base or suspended pit.